Compare the complete ordering code

ADuM1200 digital isolators

ADuM1200 has two forward isolation channels. Ordering variants differ in data rate, operating range and supply specifications, so selecting only by the base number can miss a design constraint. The table keeps the W and enhanced-product options attached to their complete ordering codes.

Industrial control console with switches, pushbuttons and a small display

Does the ADuM1200 isolation test rating define its working voltage?

No. The one-minute isolation withstand test and the permitted continuous working voltage answer different questions. Select the insulation limits for the exact device and application, then check board creepage, clearance, supply domains and signal behavior. A channel count or a withstand figure alone cannot qualify the complete isolation barrier.

How is the ordering code structured?

An ordering code combines the device identity with the fields that define its package, speed, temperature, voltage or packing, depending on the series. The example below shows the field boundaries; read the exact code from the approved BOM before comparing any offer.

ADUM1200ARZ-RL7

Example ordering code from this series

FieldWhat it controls
ModelADUM1200 provides two forward isolation channels. All listed options use the R-8 narrow-body SOIC-8 package.
Grade letterA, B and C are standard grades at 1, 10 and 25 Mbps. W S/T/U options are automotive grades at 1, 10 and 25 Mbps. The EP option uses a U grade.
Supply and temperatureStandard grades are specified from 2.7 V to 5.5 V and −40°C to +105°C. W and EP options use 3.0 V minimum; W covers −40°C to +125°C and EP covers −55°C to +125°C.
Package and finishR-8 is the narrow-body SOIC-8; Z denotes the lead-free finish. The physical pinout is unchanged across these grades.
Packing-RL7 identifies tape and reel. Tube or reel choice affects assembly preparation but not the electrical grade.

Device characteristics

ADuM1200

Isolation channels
2
Channel direction
2 forward / 0 reverse
Isolation withstand (UL 1577, 1 minute)
2,500 Vrms

These characteristics describe the device family. Exact package, grade and operating-condition limits are provided on each product page and in the manufacturer documents below.

Which ADuM1200 grade and packing option is required?

Ordinary, W and EP options differ in data rate, supply range and ambient temperature. The physical package stays R-8; the grade suffix and packing code carry the rest of the requirement.

PackageOptionsPackage codePins/balls
SOIC-812R-8 (SOIC_N)8

Package entries are compiled from the listed ordering codes. Where a device-by-package I/O count is recorded, it appears in the table; a ball or lead count alone does not establish usable I/O or footprint. Confirm the exact package drawing and device pinout.

Complete ordering options

Compare physical package and variant fields, then open an ordering code for its specifications, packing details and RFQ. All 12 options are listed below.

ADuM1200 digital isolators · ordering-code comparison
Ordering codePackageData rateSupply per sideDC
ADUM1200WURZSOIC-825 Mbps3.0 V to 5.5 V25+
ADUM1200ARZSOIC-81 Mbps2.7 V to 5.5 V24+
ADUM1200ARZ-RL7SOIC-81 Mbps2.7 V to 5.5 V24+
ADUM1200BRZSOIC-810 Mbps2.7 V to 5.5 V24+
ADUM1200CRZ-RL7SOIC-825 Mbps2.7 V to 5.5 V24+
ADUM1200CRZSOIC-825 Mbps2.7 V to 5.5 V24+
ADUM1200BRZ-RL7SOIC-810 Mbps2.7 V to 5.5 V24+
ADUM1200WSRZSOIC-81 Mbps3.0 V to 5.5 V25+
ADUM1200WTRZ-RL7SOIC-810 Mbps3.0 V to 5.5 V25+
ADUM1200WURZ-RL7SOIC-825 Mbps3.0 V to 5.5 V25+
ADUM1200BR-RL7SOIC-810 Mbps2.7 V to 5.5 V23+
ADUM1200UR-EP-RL7SOIC-825 Mbps3.0 V to 5.5 V24+

Resolve these differences before ordering

DecisionWhat to matchPurchasing consequence
Channel directionConfirm that the interface needs two channels in the forward direction.A reverse feedback signal requires a different channel arrangement.
Rate and timingCompare maximum data rate, propagation delay and pulse-width distortion for the ordered grade.A faster-looking suffix must still meet the system timing budget.
Supply and gradeRead the ordinary, W or EP variant specifications for both supply domains and temperature.Do not extend one variant’s voltage or operating range to the entire family.
Barrier and startupReview working-voltage limits, bypassing and outputs during power transitions.System insulation and startup behavior require board-level verification.
Copper traces, solder joints and small components on a green circuit board
The board layout and interface connections remain part of the isolation design review.
Hands holding test probes against a circuit board above an open electronic unit
Validate channel direction, supply conditions and interface behavior in the intended circuit.

Manufacturer documentation

Engineering and sourcing guidance

Related series to evaluate

These series support adjacent selection tasks. A related listing is not an approved replacement.

ADI · 13 ordering options

ADuM1401 digital isolators

Compare ADuM1401 four-channel, 3-forward/1-reverse isolator ordering options, data rates, supplies and wide-body SOIC packages.

ADI · 14 ordering options

LTC6811 battery stack monitors

Compare LTC6811-1 and LTC6811-2 isoSPI topologies, temperature grades, 3ZZ options and 48-lead SSOP ordering codes.

Ordering questions

What data-rate grades are listed?

Standard A, B and C grades provide 1, 10 and 25 Mbps. Automotive W grades use S, T and U for 1, 10 and 25 Mbps. The enhanced-product option uses a U grade at 25 Mbps.

What temperature and supply differences apply?

Standard grades are specified over −40°C to +105°C at 2.7 V to 5.5 V. W grades cover −40°C to +125°C at 3.0 V to 5.5 V. The EP option covers −55°C to +125°C at 3.0 V to 5.5 V.

Is the 2,500 Vrms rating a continuous working voltage?

No. It is a one-minute isolation withstand rating under UL 1577. Continuous working voltage, creepage and clearance requirements come from the datasheet insulation limits and the application. They are separate design checks.

What is ADUM1200BR-RL7?

It is a legacy ordering code supported by ADI PCN 08_0093 Rev. B. Keep the exact code in the request and confirm the offered lot and lifecycle evidence; do not shorten it to the current base code.